Procedure–Powder/ChipSamplesInstrumentcalibration/driftcorrection.PresstheAnalyzebuttonontheinstrumentscreen.Afterashortdelay,theloadingheadslide-blockwillopen.PlacetheNickelCapsulecontainingthesampleintotheopenportatthetopoftheloadinghead.PresstheAnalyzebuttonontheinstrumentscreenagain,theloadingheadslide-blockwillcloseandthelowerelectrodewillopen.Cleantheupperandlowerelectrodeeithermanuallyorremovethecrucibleandpresstheanalyzebuttontocleanwithanautomaticcleanerifapplicable.分析儀,就選上海禹重實業(yè)有限公司,有想法的可以來電咨詢!浦東新區(qū)LECO分析儀供應(yīng)商

浦東新區(qū)LECO分析儀供應(yīng)商,分析儀

Procedure–Powder/ChipSamplesInstrumentcalibration/driftcorrection.Addapproximately0.05gof***GraphitePowdertoa***GraphiteCrucible.Firmlyplacethecrucibleonthelowerelectrodetiporappropriateautoloaderposition.PresstheAnalyzebuttonontheinstrumentscreen,thelowerelectrodewillcloseandtheanalysissequencewillstartandendautomatically.Repeatsteps3bthrough3iaminimumofthreetimesforeachcalibration/driftstandardused.奉賢區(qū)進口LECO氧氮氫分析儀怎么樣上海禹重實業(yè)有限公司致力于提供分析儀,期待您的光臨!

浦東新區(qū)LECO分析儀供應(yīng)商,分析儀

MethodSelectionTwomethodsaredescribedinthisapplicationnote;eithermethodcanbeusedtoanalyzeiron,steel,nickel-,andcobalt-basealloys.ThePrecisionMethodisrecommendedforgeneraluseandwillprovidethebestprecisionandaccuracythroughoutthetypicalO,N,andHconcentrationsfoundinthisgroupofmetals;approximatecycletimeis3.5minutes.TheFastTrackmethodcanbeusedwherespeedofanalysisisacriticalcomponent;forexample,whenmoltenmetalisbeingsampledandresultsarerequiredintheshortestpossibletime.Thismethodwillproducesuitableresultsformostsamples;approximatecycletimeis2.25minutes.Asnotedabove,samplingandsamplepreparationarekeyelementstoaccurateO,N,andHdeterminationaswell.Itisuptotheusertodeterminewhichmethodbestmeetstheirneeds.

InstrumentHighlightsandFeaturesOptionalFeaturesOptionalboom-mountedtouch-screeninterfacepackage(M)promotesanergonomicworkspaceOptionalPerformancePackage(P)addsathree-stagecarriergaspurificationsystem,andadual-loopgasdosemoduleOptionalDualCoolingPackage(D)addsanintegratedliquid-to-airradiatorwithdualcoolingfans.ThisDCoptiongivestheuserthechoiceofliquid-to-liquidcooling,liquid-to-aircooling,oracombinationofbothOptionalintegratedautocleaner(H)automaticallycleanstheupperelectrodeandlowerelectrodetipOptional20-sampleshuttleloaderavailable上海禹重實業(yè)有限公司為您提供分析儀,有想法可以來我司咨詢!

浦東新區(qū)LECO分析儀供應(yīng)商,分析儀

Procedure–Powder/ChipSamplesDeterminetheinstrumentblank.PresstheAnalyzebuttonontheinstrumentscreen,thelowerelectrodewillcloseandtheanalysissequencewillstartandendautomatically.Repeatsteps2bthrough2gaminimumofthreetimes.Settheblankfollowingtheprocedureoutlinedintheoperatorsinstructionmanual.Instrumentcalibration/driftcorrection.LoginaminimumofthreeStandardreps.Weighapproximately***gramsofacalibration/driftstandardintoa***NickelCapsule;enterthemassandstandardidentificationintoappropriaterepfields.Ifapplicable,placethenickelcapsuleintheappropriateautoloaderposition.Note:LECOReferenceMateria***onotrequirepreparation.Seepreparationstatementonthereferencematerialcertificate.SolidStandardsmaybeusedtocalibratewhenchiporpowderstandardsarenotavailable.上海禹重實業(yè)有限公司為您提供分析儀,期待您的光臨!閔行區(qū)進口LECO氧氮氫分析儀

分析儀,就選上海禹重實業(yè)有限公司,讓您滿意,期待您的光臨!浦東新區(qū)LECO分析儀供應(yīng)商

氧氮氫分析儀的常見故障及解決方法儀器啟動時顯示。沒有水流。系統(tǒng)分析電流切斷,分析停止。這是水流探測器不正常,水泵不工作,管道堵塞。將儀器的右面板取下,觀察水流探測器,用手擠壓補水塑料水瓶,發(fā)現(xiàn)水流正常,顯示正常,證明水流探測器正常,管道暢通。啟動循環(huán)水泵,但分析儀顯示沒有水流,此時可判定水泵不正常。打開水泵轉(zhuǎn)子密封口,啟動泵發(fā)現(xiàn)電機正常運轉(zhuǎn),此時關(guān)閉進水,拆下水泵,發(fā)現(xiàn)葉輪脫落。經(jīng)了解,判定是由于外部冷卻水停水,儀器內(nèi)循環(huán)水溫過高(水溫應(yīng)≤70℃),致使葉輪(葉輪材料PVC)熱脹并脫軸。用粘合劑粘合葉輪后再粘于葉輪軸上,待粘合劑凝固后試車,儀器運行正常。浦東新區(qū)LECO分析儀供應(yīng)商

上海禹重實業(yè)有限公司是一家有著雄厚實力背景、信譽可靠、勵精圖治、展望未來、有夢想有目標,有組織有體系的公司,堅持于帶領(lǐng)員工在未來的道路上大放光明,攜手共畫藍圖,在上海市等地區(qū)的儀器儀表行業(yè)中積累了大批忠誠的客戶粉絲源,也收獲了良好的用戶口碑,為公司的發(fā)展奠定的良好的行業(yè)基礎(chǔ),也希望未來公司能成為*****,努力為行業(yè)領(lǐng)域的發(fā)展奉獻出自己的一份力量,我們相信精益求精的工作態(tài)度和不斷的完善創(chuàng)新理念以及自強不息,斗志昂揚的的企業(yè)精神將**上海禹重實業(yè)供應(yīng)和您一起攜手步入輝煌,共創(chuàng)佳績,一直以來,公司貫徹執(zhí)行科學管理、創(chuàng)新發(fā)展、誠實守信的方針,員工精誠努力,協(xié)同奮取,以品質(zhì)、服務(wù)來贏得市場,我們一直在路上!