浙江LECO分析儀廠家直銷

來源: 發(fā)布時間:2021-09-12

Procedure - Solid Samples

Instrument calibration/drift correction.

Add approximately 0.05 g of *** Graphite Powder to a *** Graphite Crucible.

Firmly place the crucible on the lower electrode tip or appropriate autoloader position.

Press the Analyze button on the instrument screen, the lower electrode will close and the analysis sequence will start and end automatically.

Repeat steps 3b through 3j a minimum of three times for each calibration/drift standard used.

Calibrate/drift following the procedure outlined in the operator's instruction manual.


氧氮氫分析儀選哪家?給你推薦上海禹重科技!浙江LECO分析儀廠家直銷

浙江LECO分析儀廠家直銷,分析儀

Procedure – Powder/Chip Samples

Determine the instrument blank.


Press the Analyze button on the instrument screen, the lower electrode will close and the analysis sequence will start and end automatically.


Repeat steps 2b through 2g a minimum of three times.


Set the blank following the procedure outlined in the operator's instruction manual.


Instrument calibration/drift correction.

Login a minimum of three Standard reps.


Weigh approximately *** grams of a calibration/drift standard into a *** Nickel Capsule; enter the mass and standard identification into appropriate rep fields. If applicable, place the nickel capsule in the appropriate autoloader position.


Note: LECO Reference Materia***o not require preparation. See preparation statement on the reference material certificate. Solid Standards may be used to calibrate when chip or powder standards are not available.




山西專業(yè)分析儀采購高級診斷程序包括全數(shù)字化的在線操作手冊、維護模擬演示、圖片說明等提供快速指導。

浙江LECO分析儀廠家直銷,分析儀

氧氮氫分析儀的常見故障及解決方法:

氧和氮空白值超過20。這是由于氣流小,不能將爐子中的空氣驅趕出去。可調節(jié)氣體流量,調節(jié)載氣壓力在0.2~0.4MPa。接通儀器載氣,放一個石墨坩堝在下電極上,打開主電源開關,點擊軟件上的關爐按鈕,關閉爐子并等待10s。調節(jié)流量調節(jié)器,直到流量計a顯示為30L/h,打開爐子。調節(jié)調節(jié)器直到流量計b顯示為50L/h,再次關閉爐子。如果以上設置不穩(wěn)定,則增加流量至100L/h,反復調節(jié)直至儀器穩(wěn)定。

Procedure - Solid Samples:

--Instrument calibration/drift correction.

Place the nickel basket containing the calibration/drift standard into the open port at the top of the loading head.

Press the Analyze button on the instrument screen again, the loading head slide-block will close and the lower electrode will open.

Clean the upper and lower electrode manually, or, if applicable, remove the crucible and press the analyze button to clean with the automatic cleaner.



新型氣路管道減少氣路連接閥,使得漏氣,斷路故障更少。

浙江LECO分析儀廠家直銷,分析儀

LECO—Your source for total analytical solutions


CS CS 844 and 744 Series: Carbon/Sulfur by Combustion

Carbon and sulfur determination by combustion infrared detection

Quick, accurate, and affordable determination for both production control and research

Calibration, analysis, evaluation, and diagnostic functions accessible via user-friendly brand software



GDS GDS 500A and 850A Atomic Emission Spectrometers

Spectral range from 120 to 800 nm

Continuous profile of concentration/thickness

Large, dynamic range with concentrations from ppm to 100% by weight

Short analysis time (minutes)





氧氮氫分析儀選哪家?給您推薦上海禹重!浙江LECO氧氮氫分析儀價格

力可創(chuàng)新的批次和重復樣品數(shù)據(jù)分組功能極大簡化了樣品結果輸出和結果標準偏差的自動計算。浙江LECO分析儀廠家直銷

ONH836系列:氧氮氫分析儀(熔融法)

軟件特點和優(yōu)勢

Cornerstone氧氮氫分析軟件分成4個主要部分:分析、診斷、設定、儀器,界面可以快速導航和組織。工具條、滑動條和下拉式菜單簡化了校正和數(shù)據(jù)處理的參數(shù)設定。分析軟件同時包括實時的環(huán)境參數(shù)的監(jiān)測,提供完整的系統(tǒng)圖表模擬。高級診斷程序包括全數(shù)字化的在線操作手冊、維護模擬演示、圖片說明等提供快速指導。Cornerstone氧氮氫分析軟件同時支持***的數(shù)據(jù)文檔格式和可變的報告格式。 浙江LECO分析儀廠家直銷